1.Appearance
- Horizontal cylinder, silver body with red burner and logo, compact & stable layout.
2.Key Features
- High-efficiency disc tube heating
- Closed-loop thermal oil, low heat loss
- Positive pressure combustion
3.Applications
- Automatic control + remote monitoring, ideal for high-temperature processes in chemical, textile, food and rubber industries.
Organic Heat Carrier Heater Specifications
| Parameter | Unit | YYW-350YQ | YYW-600YQ | YYW-900YQ | YYW-120YQ | YYW-150YQ | YYW-180YQ | YYW-230YQ | YYW-290YQ |
| Rated Thermal Power | MW | 0.35 | 0.6 | 0.9 | 1.2 | 1.5 | 1.8 | 2.3 | 2.9 |
| Rated Working Pressure | MPa | 30×10⁴ | 50×10⁴ | 75×10⁴ | 100×10⁴ | 130×10⁴ | 150×10⁴ | 200×10⁴ | 250×10⁴ |
| Design Thermal Efficiency | % | ≥92 | ≥92 | ≥92 | ≥92 | ≥92 | ≥92 | ≥92 | ≥92 |
| Max Working Temperature | ℃ | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 |
| Medium Circulation Flow | m³/h | 40 | 58 | 100 | 100 | 100 | 160 | 160 | 200 |
| Inlet Diameter | DN | 65 | 80 | 80 | 125 | 125 | 150 | 150 | 150 |
| Outlet Diameter | DN | 100 | 100 | 125 | 125 | 125 | 150 | 150 | 200 |
| System Power Consumption | KW | 10 | 15 | 28 | 36 | 44 | 54 | 50 | 60 |
| Design Fuel | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | |
| Medium Volume in Furnace | m³ | 0.4 | 0.6 | 0.6 | 0.8 | 1.2 | 2.1 | 2.6 | 3.5 |
| Fuel Consumption – Light Oil | kg/h | 36 | 64 | 89 | 125.6 | 155 | 164 | 246 | 292 |
| Fuel Consumption – Natural Gas | Nm³/h | 45 | 75 | 108 | 153.4 | 188 | 173 | 302 | 344 |
| Transport Weight | t | 1.3 | 4 | 5.3 | 5.6 | 7.3 | 8.7 | 13.7 | 15.2 |
| Overall Dimension – Length | mm | 1600 | 2000 | 3400 | 3500 | 4600 | 4700 | 5200 | 5400 |
| Overall Dimension – Width | mm | 1500 | 1800 | 1900 | 2200 | 2300 | 2500 | 2650 | 2800 |
| Overall Dimension – Height | mm | 1800 | 2000 | 2100 | 2300 | 2400 | 2500 | 2600 | 2800 |
| Parameter | Unit | YYW-3500YQ | YYW-4800YQ | YYW-5800YQ | YYW-7000YQ | YYW-8200YQ | YYW-9400YQ | YYW-10500YQ | YYW-14000YQ |
| Rated Thermal Power | MW | 3.5 | 4.8 | 5.8 | 7 | 8.2 | 9.4 | 10.5 | 14 |
| Rated Working Pressure | MPa | 300×10⁴ | 400×10⁴ | 500×10⁴ | 600×10⁴ | 700×10⁴ | 800×10⁴ | 900×10⁴ | 1200×10⁴ |
| Design Thermal Efficiency | % | ≥92 | ≥92 | ≥92 | ≥92 | ≥92 | ≥92 | ≥92 | ≥92 |
| Max Working Temperature | ℃ | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 |
| Medium Circulation Flow | m³/h | 200 | 260 | 300 | 340 | 400 | 520 | 600 | 680 |
| Inlet Diameter | DN | 200 | 200 | 250 | 250 | 250 | 300 | 300 | 350 |
| Outlet Diameter | DN | 200 | 200 | 250 | 250 | 250 | 300 | 300 | 350 |
| System Power Consumption | KW | 60 | 85 | 100 | 110 | 140 | 170 | 195 | 250 |
| Design Fuel | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | Light Oil / Natural Gas | |
| Medium Volume in Furnace | m³ | 7 | 7.8 | 8.4 | 8.8 | 10.5 | 11.2 | 11.5 | 13 |
| Fuel Consumption – Light Oil | kg/h | 356 | 457 | 570 | 646 | 801 | 916 | 1085 | 1375 |
| Fuel Consumption – Natural Gas | Nm³/h | 432 | 554 | 693 | 832 | 973 | 1113 | 1310 | 1670 |
| Transport Weight | t | 20.1 | 29.2 | 37.3 | 47.5 | 54 | 58.6 | 65.5 | 108.8 |
| Overall Dimension – Length | mm | 6200 | 6800 | 7400 | 7800 | 8000 | 8500 | 8800 | 11200 |
| Overall Dimension – Width | mm | 2900 | 3200 | 3300 | 3400 | 3500 | 3600 | 3800 | 3900 |
| Overall Dimension – Height | mm | 2800 | 3300 | 3400 | 3500 | 3500 | 3600 | 3900 | 3900 |